APC InRow RC - Kolmijalkainen ilmastointilaite jäähdytetty vesi - 380 - 415 V - musta - 42U
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Tuotetta ei ole varastossa. Lisätietoja

Kuljetuksen hinta 150,60 Kuormalavatoimitus katutasolle (arkisin 8:00-16:00)
– Takaraja klo 15.00 toimituksen lähtöön samana päivänä

Toimituskulut on laskettu vastaanottajan postinumeron perusteella: - Vaihda postinumero
Syötä postinumero toimitusta varten: Tallenna

Loppuunmyyty

Tuotetta ei ole varastossa.

EUR 36.546,10
ilman ALV 29.120,40
Kokonaishinta sis. toimitus 36.696,70
Ilmoita minulle, kun tuotetta on jälleen tarjolla varastossa
Manageability

Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Real-Time Capacity Monitoring
Real-time display of current and available cooling.

Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.

Total Cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.

Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.

Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.

Agility

Casters
Provides flexibility to move the unit to wherever cooling is required.

Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Modular design
Modular design provides scalable solutions to add cooling as demand increases.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.