APC Smart-UPS 3000 LCD - UPS (rackversio) - AC 220/230/240 V - 2,7 kW - 3000 VA - RS-232, USB - output-stikforbindelser: 9 - 2U - for P/N: AR3003, AR3003SP, AR3006, AR3006SP, AR3103, AR3103SP, AR3106, AR3106SP, AR3357X674
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Päävarastossa
Päävarastossa. Tilaa ennen klo 15:00 niin pyrimme lähettämään tuotteen tänään. (arkipäivisin) Lisätietoja

Kuljetuksen hinta 148,80 Kuormalavatoimitus katutasolle (arkisin 8:00-16:00)
– Takaraja klo 15.00 toimituksen lähtöön samana päivänä

Toimituskulut on laskettu vastaanottajan postinumeron perusteella: - Vaihda postinumero
Syötä postinumero toimitusta varten: Tallenna

VARASTOTARJOUS

Tuotetta on päävarastossa 1 kappaletta

Nykyinen hinta on voimassa niin kauan kuin erää on jäljellä varastossa.

EUR 2.351,31
ilman ALV 1.896,22
Kokonaishinta sis. toimitus 2.500,11
Intuitive LCD interface\nProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.\n\nPredictive replace battery date\nDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.\n\nGreen mode\nPatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\n\nEnergy meter\nProvides actual kilowatt hours of usage for energy conscious users.\n\nOutlet group control\nTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).\n\nSequenced shutdown and restart\nConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).\n\nAudible alarms\nProvide notification of changing flywheel conditions\n\nInfraStruXure Central compatible\nEnables centralized management via APC InfraStruXure® Central.\n\nPure sine wave output on battery\nSimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.\n\nSingle switched outlet group\nSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.\n\nWide input voltage range\nDesigned for harsh electrical environments to save battery life.\n\nBattery failure notification\nProvides early-warning fault analysis on batteries enabling timely preventive maintenance\n\nHigh online efficiency\nReduces utlility costs, generates less heat.\n\nLED Indicators\nProvide easy-to-read status of your utility power conditions, UPS and battery.\n\nCold-start capable\nProvides temporary battery power when the utility power is out.\n\nSerial Connectivity\nUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.\n\nHot-swappable batteries\nEnsures clean, uninterrupted power to protected equipment while batteries are being replaced\n\nDisconnected battery notification\nWarns when a battery is not available to provide backup power.\n\nAutomatic self-test\nPeriodic battery self-test ensures early detection of a battery that needs to be replaced.\n\nAutomatic restart of loads after UPS shutdown\nAutomatically starts up the connected equipment upon the return of utility power.\n\nAdjustable voltage-transfer points\nMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.\n\nAdjustable voltage sensitivity\nProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.\n\nAudible alarms\nProvides notification of changing utility power and UPS conditions.\n\nUser-replaceable batteries\nIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\n\nUSB connectivity\nProvides management of the UPS via a USB port (not available on all models).\n\nSerial Connectivity\nProvides management of the UPS via a serial port.\n\nTemperature-compensated battery charging\nProlongs battery life by regulating the charge voltage according to battery temperature.\n\nBoost and Trim Automatic Voltage Regulation (AVR)\nGives higher application availability by correcting low and high voltage conditions without using the battery.\n\nIntelligent battery management\nMaximizes battery performance, life, and reliability through intelligent, precision charging.\n\nSafety-agency approved\nEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.\n\nNetwork manageable\nProvides remote management of the UPS over the network.\n\nFrequency and voltage regulation\nGives higher application availability by correcting poor frequency and voltage conditions without using the battery.\n\nAdjustable voltage sensitivity\nProvides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.\n\nPredicitive failure notification\nProvides early-warning fault analysis ensuring proactive component replacement.